{"id":17772,"date":"2021-03-31T09:38:55","date_gmt":"2021-03-31T06:38:55","guid":{"rendered":"https:\/\/www.toode.ee\/?page_id=17772"},"modified":"2021-03-31T09:44:14","modified_gmt":"2021-03-31T06:44:14","slug":"installation-recommendations-for-safety-accessories","status":"publish","type":"page","link":"https:\/\/www.toode.ee\/en\/installation-recommendations-for-safety-accessories\/","title":{"rendered":"Installation Recommendations for Safety Accessories"},"content":{"rendered":"<p style=\"text-align: justify;\"><strong>For safe performance of roof maintenance works, an optimal complete solution should be worked out with the assistance of a master roofer. Requirements established by standards should not be forgotten either. What is really important?<\/strong><\/p>\n<p style=\"text-align: justify;\"><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-7038\" src=\"https:\/\/www.toode.ee\/wp-content\/uploads\/2016\/04\/turva002-3.jpg\" alt=\"\" width=\"889\" height=\"226\" srcset=\"https:\/\/www.toode.ee\/wp-content\/uploads\/2016\/04\/turva002-3.jpg 889w, https:\/\/www.toode.ee\/wp-content\/uploads\/2016\/04\/turva002-3-768x195.jpg 768w\" sizes=\"(max-width: 889px) 100vw, 889px\" \/><\/p>\n<p style=\"text-align: justify;\">Estonian standard EVS 812-3:2018, Regulation \u201cFire Safety Requirements to Buildings and Requirements to Fire Water Supply\u201d of the Government or the Republic, and the Fire Safety Act require:<br \/>\n\u2013 Installation of a fixed ladder <strong>on all roofs from inclination 11\u00b0<\/strong>(approx. 1:5).<br \/>\n\u2013 In case of buildings higher than 8.5m, access to the roof must be provided through the attic and\/or roof hatch or using a <strong>fixed (stationary)<\/strong> external emergency ladder.<br \/>\n\u2013 To a chimney <strong>higher than 1.2m from the roof surface<\/strong>, a cleaning platform with the necessary access ladder must be installed.<\/p>\n<p style=\"text-align: justify;\">What does \u201cfixed\u201d mean? There are wooden ladders of dubious strength and stability on the roofs of many older buildings. Furthermore, to a new tin roof, the ladder should be fixed firmly, to avoid surface coating damages caused by a movable wooden or aluminium ladder. Ask the roofer to determine the best locations for ladders and walkways ensuring convenience, efficiency, and safety of use. The house owner\u2019s habits (for example, heating-related), vandalism resistance (a ladder should not be installed onto a wall facing the street), and visual appearance should be considered.<\/p>\n<p style=\"text-align: justify;\"><strong>It is important to comply with requirements to walkway and ladder roof installation.<\/strong> Several standards apply to walkways and ladders used on the roofs, which establish the requirements to fasteners. The manufacturers\u2019 installation instructions specify the maximum allowed spacing of the fasteners.<\/p>\n<h3 style=\"text-align: justify;\">Recommendations on correct installation of safety accessories<\/h3>\n<p style=\"text-align: justify;\">\u2013 The placement of safety accessories must comply with a well-<strong>considered, optimal and logical complete<img decoding=\"async\" class=\"alignright size-medium wp-image-17244\" src=\"https:\/\/www.toode.ee\/wp-content\/uploads\/2020\/11\/IMGM6894-200x300.jpg\" alt=\"\" width=\"200\" height=\"300\"> solution.<\/strong><br \/>\n\u2013 In case of roofing penetrated by screws, the fasteners of safety accessories must coincide with the battens. In case of Class2 installation, the outermost fasteners must coincide with end rafters.<br \/>\n\u2013 The fasteners may not damage the roofing underlay membrane, except at the crossing of the rafter, spacer, and batten.<br \/>\n\u2013 In case of rolled metal roofs and Classic-type roofing materials, at the area of safety products attachment, the spacing of roofing fasteners to the battens must be shortened. In case of snow guards and bridges, it is important for the sheet metal panel located under the upper part of their attachment supports to be fastened to the batten at the same location. At such areas, the \u201clifting\u201d resulting from loads is the greatest, and in case of inadequate fastening, the panel could be torn up with the snow guard or bridge fastener.<br \/>\n\u2013 In case of rolled metal roofs and Classic-type roofing, no penetrating holes (screw holes) in the roofing resulting from safety product attachment are allowed.<br \/>\n\u2013 If possible, roof and wall ladder attachment to chimneys should be avoided. There are other products available for this purpose.<br \/>\n\u2013 When planning the placement of safety accessories, if possible, it should be made sure that snow accumulating behind them does not cause excessive local snow loads or potential leaks resulting therefrom (e.g., at the valleys and other elements of profiled and low-pitched roofs).<br \/>\n\u2013 Never use safety accessories for purposes other than intended. For example, pipe-style snow guards as ladders or safety rails. Round pipes rotate in their holders and do not make for safe footing, etc.<br \/>\n\u2013 When installing safety ropes and rails on bridges or ladders, the specifications and requirements of<\/p>\n<p><img decoding=\"async\" class=\"size-medium wp-image-17238 alignright\" src=\"https:\/\/www.toode.ee\/wp-content\/uploads\/2020\/11\/DJI_0557-300x169.jpg\" alt=\"\" width=\"300\" height=\"169\"><\/p>\n<p style=\"text-align: justify;\">Class1 and Class2 must be complied with.<br \/>\n\u2013 In case of very low inclinations, installation of a roof ladder is altogether pointless. It is impossible to walk on them safely. In case of low inclinations, roof bridges must be preferred or step plates installed on ladders used. Bridges are never installed along the panel, only crosswise. When using a ladder on a low-pitched roof, installation of plates for safe walking on the ladder rungs is recommended.<br \/>\n\u2013 The bottommost rung of a wall ladder must not be accessible to children.<br \/>\n\u2013 In case of high wall ladders, the need for a safety cage should be considered.<br \/>\n\u2013 In case of production and public buildings, the wall ladder frame width exceeds that of residential<img loading=\"lazy\" decoding=\"async\" class=\"alignright size-medium wp-image-13715\" src=\"https:\/\/www.toode.ee\/wp-content\/uploads\/2017\/06\/aaaIMGP1641-300x237.jpg\" alt=\"\" width=\"300\" height=\"237\"> buildings.<br \/>\n\u2013 The fasteners used with safety accessories (screws, bolts, nuts, seals) are special products tested for the loads associated with safety accessories, not general-purpose products purchased from a hardware store.<br \/>\n\u2013 The fasteners must be suitable for outdoor use.<br \/>\n\u2013 Snow guard placement must consider the resulting changes in load and its possible influence on the stability of the building.<br \/>\n\u2013 When determining the need for snow guards, proceed from the principle: As many as necessary, as few as possible.<\/p>\n<p style=\"text-align: justify;\"><strong>It is important to check the tightness of safety product fasteners regularly.<\/strong> We recommend entrusting this job to a master roofer. The situation is somewhat the same as in case of requirements to periodical heating equipment inspection.<br \/>\n\u2013 If the spacing of fastening solutions is increased, proper functioning of the products need not be ensured; always comply with the manufacturer\u2019s installation instructions. These are usually drawn up based on the material properties and test results.<br \/>\n\u2013 When installing a roof ladder, the first ladder rung should be vertically aligned with the eaves or edge of roofing, so that a ladder mounted could be supported against the first rung of the stationary roof ladder. This avoids damaging the eaves or roofing edge by the temporary ladder.<br \/>\n\u2013 Do not split the products with abrasive cutting discs; use a hacksaw.<br \/>\n\u2013 Damaged products must be replaced with new ones.<br \/>\n\u2013 If possible, avoid using sheet metal snow guards. A sheet metal snow guard is very efficient as a snow barrier and may thus be subject to much greater loads as compared to pipe-style snow guards, especially in case of wet snow. As a consequence, the sheet metal snow guard may be deformed or torn out of the batten with the support element. The resulting hole in the roofing is impossible to patch in a waterproof manner.<br \/>\n\u2013 The seller of safety products must submit the required certificates and product information. Require them already in the request for quotation stage.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-large wp-image-7628\" src=\"https:\/\/www.toode.ee\/wp-content\/uploads\/2016\/04\/P1085264-1024x539.jpg\" alt=\"\" width=\"840\" height=\"442\"><\/p>\n<h3 style=\"text-align: justify;\">Annual inspection of safety accessories must include:<\/h3>\n<p style=\"text-align: justify;\">\u2013 Inspection of the tightness of element joints.<br \/>\n\u2013 Inspection of the attachment of roof bridge and ladder sets to the roof or roofing (variations are possible depending on the roofing).<br \/>\n\u2013 At locations subject to regular increased snow load, the inspections must be carried out more often, as required, but not less frequently than once a year.<br \/>\n\u2013 In case of excessive snow and ice load, roof bridges and ladders must be cleaned regularly.<br \/>\n\u2013 Inspect the condition of the surface coating of products (paint or zinc coating, in case of galvanized products). If necessary, use touch up paint to repair the damages or replace the products.<br \/>\n\u2013 Products damaged mechanically or otherwise must be repaired or replaced.<\/p>\n<hr>\n<p style=\"text-align: justify;\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-11399\" src=\"https:\/\/www.toode.ee\/wp-content\/uploads\/2016\/06\/toodelogopng-1-300x194.png\" alt=\"\" width=\"96\" height=\"62\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>For safe performance of roof maintenance works, an optimal complete solution should be worked out with the assistance of a master roofer. Requirements established by standards should not be forgotten either. What is really important? Estonian standard EVS 812-3:2018, Regulation \u201cFire Safety Requirements to Buildings and Requirements to Fire Water Supply\u201d of the Government or [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"ngg_post_thumbnail":0,"footnotes":""},"class_list":["post-17772","page","type-page","status-publish","hentry"],"acf":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/www.toode.ee\/en\/wp-json\/wp\/v2\/pages\/17772","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.toode.ee\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.toode.ee\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.toode.ee\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.toode.ee\/en\/wp-json\/wp\/v2\/comments?post=17772"}],"version-history":[{"count":0,"href":"https:\/\/www.toode.ee\/en\/wp-json\/wp\/v2\/pages\/17772\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.toode.ee\/en\/wp-json\/wp\/v2\/media?parent=17772"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}